ZOLL CPR-D Padz | Adult Replacement Pads for ZOLL AED Plus (8900-0800-01)
The longest-lasting ZOLL AED pads for your ZOLL AED Plus. Features the exclusive Real CPR Help® sensor that gives you real-time feedback on compression rate and depth during a rescue.
- OEM Part Number: 8900-0800-01 (Adult CPR-D padz)
- Shelf Life: Guaranteed 5 Years (Lowest cost of ownership)
- Design: One-piece electrode for error-proof placement
- Includes: Attached Rescue Accessory Kit (Scissors, Gloves, Razor, Mask, Wipes)
- Status: ✅ In Stock & Ships Free
Genuine ZOLL CPR-D-padz® (8900-0800-01) | Adult Replacement Pads for ZOLL AED Plus
The ZOLL CPR-D-padz® (Part #8900-0800-01) are the official OEM ZOLL AED plus replacement pads engineered specifically for the ZOLL AED Plus and ZOLL AED Pro defibrillators. Unlike conventional two-piece defibrillator electrodes, these ZOLL AED pads feature an innovative, one-piece pre-connected design with an integrated Real CPR Help® sensor to track chest compressions in real time.
Jump to: Compatibility | Emergency Placement Guide | Installation Instructions | Frequently Asked Questions | Technical Specifications
⭐ Why the “Real CPR Help” Sensor Matters
These are the only ZOLL defibrillator pads that allow your AED to evaluate chest compressions during a rescue. The built-in accelerometer sensor measures both the rate and depth of every push, triggering active voice prompts such as “Push Harder” or “Good Compressions.” Without this sensor, your AED Plus cannot provide active CPR coaching during sudden cardiac arrest. Learn how this technology measures depth and rate in our deep dive: How ZOLL CPR-D Padz & Real CPR Help Technology Work.
✅ 5-YEAR SHELF LIFE (Industry-Leading Longevity)
Standard AED electrode pads expire every 2 years. Genuine ZOLL CPR-D pads provide a full 5-year expiration date from manufacture, giving the ZOLL AED Plus the lowest total cost of ownership in the AED industry.
⚡ Complete Your Rescue Kit Refresh
If your ZOLL AED plus pads are reaching expiration, your lithium batteries are likely nearing their replacement window as well. Keep your defibrillator 100% rescue ready.
Add ZOLL AED Plus Replacement Batteries (Sleeve of 10 Duracell 123A Lithium) →
Key Benefits of ZOLL CPR-D-padz Adult Electrodes
- Error-Proof One-Piece Placement: Avoid pad placement confusion under pressure. Simply place the red sternum cross in the center of the chest, and the apex and sternum electrode pads naturally align in the correct anatomical positions.
- Complete Attached Rescue Accessory Kit: Every sealed package of CPR D padz includes a zippered CPR kit containing heavy-duty trauma shears, medical gloves, a prep razor, an emergency barrier face mask, and antimicrobial dry wipes.
- Extended 5-Year Standby Life: Pre-connect these replacement pads for ZOLL AED Plus and leave them sealed in the AED case for up to five years without worry.
ZOLL Defibrillator Pad Compatibility Chart
| Defibrillator Model | Compatibility Status | Recommended Pad Type |
|---|---|---|
| ZOLL AED Plus | ✅ 100% Compatible | Primary standard adult electrode (ZOLL AED Plus Units). |
| ZOLL AED Pro | ✅ 100% Compatible | Fully approved for clinical, EMS, and workplace use. |
| ZOLL AED 3 | ❌ Incompatible | Requires ZOLL CPR Uni-padz. |
| Pediatric Patients (< 55 lbs) | ❌ Adult Only (> 55 lbs) | Requires specialized ZOLL Pedi-padz® II (see our Pediatric AED Compliance Guide). |
How to Apply ZOLL CPR-D Padz During a Cardiac Emergency
Follow these four clinical steps when deploying ZOLL CPR D pads during sudden cardiac arrest:
- Prepare the Patient’s Chest: Expose the victim’s bare chest. Use the attached rescue kit to cut clothing with shears, shave excessive chest hair with the razor, and dry sweat or moisture using the included wipe.
- Position the Red Cross (Landmark Sensor): Hold the CPR-D padz assembly by the central plastic sensor. Place the red cross directly on the center of the patient’s sternum, right between the nipples.
- Pull Tab 2 and Adhere the Top Pad: Hold the sensor in place with one hand. Grasp the “Tab 2” handle, peel the backing away, and press the upper electrode firmly onto the victim’s upper right chest (under the collarbone).
- Pull Tab 3 and Adhere the Bottom Pad: Grasp “Tab 3,” peel off the protective liner, and smooth the lower electrode over the victim’s lower left ribs (lateral torso). Begin chest compressions by placing your hands directly over the center sensor.
How to Install & Pre-Connect ZOLL AED Plus Replacement Pads
To keep your AED Plus in a “Rescue Ready” state, pre-connect your pads prior to an emergency:
- Inspect the Expiration Date: Check the yellow expiration tag printed on your new ZOLL 8900-0800-01 package. Confirm the date is five years out.
- Unplug Old Electrodes: Open the cover of the ZOLL AED Plus. Disconnect the old green wiring connector and discard expired pads responsibly.
- Plug in the New CPR-D Padz: Firmly insert the green plastic connector into the pad socket located on the upper face of the AED Plus. Listen for the device to acknowledge connection.
- Tuck and Align Expiration Tag: Fold the sealed pad package neatly into the recessed lid compartment, ensuring the yellow expiration label faces upward through the clear lid window for monthly inspection checks.
Facility Tip: For a step-by-step walk-through on battery resets, monthly inspection checklists, and troubleshooting beeps, read our Complete Facility Guide to ZOLL AED Plus Maintenance.
Frequently Asked Questions About ZOLL AED Pads
There is no functional difference. “CPR-D-padz” is ZOLL Medical’s official registered trademark spelling, whereas customers and safety managers commonly search for “ZOLL CPR-D pads.” Both refer to the identical OEM one-piece adult electrode (Part #8900-0800-01).
Authentic OEM ZOLL CPR-D-padz generally cost between $190 and $240. While standard 2-year AED pads cost around $70 to $100 per pair, ZOLL’s 5-year standby life means you only purchase pads twice in a decade, reducing overall AED maintenance costs.
No. ZOLL CPR-D-padz are calibrated strictly for adult cardiac victims aged 8 and older or weighing more than 55 lbs (25 kg). For pediatric rescues, use ZOLL Pedi-padz II, which attenuate defibrillation energy levels down to pediatric-safe thresholds. Read our complete guide on pediatric AED compliance and pad placement.
No. All ZOLL defibrillator pads are single-use medical consumables. Once the conductive hydrogel is exposed to air or applied to skin, it degrades. Pads must be replaced immediately after deployment or once they reach their printed expiration date.
Yes. Every authentic set of ZOLL CPR-D-padz comes factory sealed with an attached clear accessory pouch containing trauma shears, a surgical prep razor, medical gloves, an emergency CPR barrier mask, and dry wipes.
Technical Specifications: ZOLL 8900-0800-01
| Product Name | ZOLL CPR-D-padz® Adult Defibrillation Electrodes |
| Manufacturer / Brand | ZOLL® Medical Corporation |
| OEM Part Number | 8900-0800-01 |
| Shelf Life | 5 Years (from date of manufacture) |
| CPR Sensor Technology | Real CPR Help® embedded accelerometer |
| Electrode Format | One-piece pre-connected polymer conductive gel |
| Lead Wire Length | 48 inches (1.2 meters) |
Ensure your emergency equipment remains compliant with workplace and OSHA health standards by routinely monitoring the yellow expiration tag on your ZOLL defibrillator pads.