Cardiac Science Powerheart G5 Adult Intellisense CPR Feedback Pads (XELAED002B / XELAED002A)

IN STOCK
Official OEM Cardiac Science • Fresh 2-Year Dates

Official OEM Cardiac Science Powerheart G5 Adult Intellisense CPR Feedback Pads (Part # XELAED002B / XELAED002A). Includes pre-attached ICPR device for real-time voice and text guidance on compression depth and pacing.

  • Dual Part Number Compatibility: Exact replacement for XELAED002B, XELAED002A, and XELAED002C.
  • Non-Polarized Electrodes: Either pad can be placed in either chest position to eliminate rescue delays.
  • Free FedEx Ground Shipping: Fast, tracked delivery straight from our Midwest facility.
Need a Battery Replacement?
+ Add G5 4-Year Battery →
Prefer Standard Pads (No CPR Device)?
View XELAED001B Pads →

$291.59 $268.00

Sale Ends In:

Cardiac Science Powerheart G5 Adult Intellisense CPR Feedback (ICPR) Pads (Part # XELAED002B / XELAED002A)

Deliver high-quality CPR with genuine OEM Cardiac Science Powerheart G5 Adult Defibrillation Pads with Intellisense CPR Feedback (Part # XELAED002B / XELAED002A). Designed specifically for the Powerheart G5 AED (Semi-Automatic and Fully Automatic models), these specialized electrodes feature an integrated ICPR sensor that measures the exact depth and rate of chest compressions in real time according to American Heart Association (AHA) guidelines.

📦 IN STOCK • SHIPS FREE VIA FEDEX • FRESH FACTORY EXPIRATION DATES

Real-Time CPR Feedback Technology (ICPR)

Sudden cardiac arrest survival depends heavily on effective chest compressions. The Intellisense CPR (ICPR) device is pre-attached to the defibrillation pads and rests directly between the rescuer’s hands and the patient’s sternum:

  • Active Voice & Text Coaching: If compressions are too shallow, the G5 voice prompt instructs “Press harder and fully release.” Once compression depth reaches 2 to 2.4 inches, the AED encourages with “Good compressions.”
  • Metronome Rate Pacing: Built-in metronome guides rescuers to maintain the recommended 100 to 120 compressions per minute.
  • Rescue Ready® Discretion: If an experienced rescuer or EMS professional prefers not to use the feedback sensor, it can simply be set aside without interrupting cardiac monitoring or defibrillation therapy.
  • Dual-Language On-the-Fly Switching: Toggling the G5’s language button during a rescue automatically switches both the defibrillator prompts and CPR coaching instructions into the secondary language.

Complete Your Powerheart G5 Maintenance Kit

Powerheart G5 4-Year Battery

Check your battery gauge. If your G5 battery is nearing its 4-year service life, replace it to maintain active standby readiness.

+ Add G5 Battery →

Don’t Need CPR Feedback?

Save on replacement costs with standard adult electrodes without the CPR feedback sensor.

View Standard G5 Pads (XELAED001B) →

Technical Specifications

Specification Detail
Manufacturer Part Number (MPN) XELAED002B
Alternate Part Numbers XELAED002A, XELAED002C
Leadwire / Cable Length 51.5 inches (130 cm) pre-connected
Electrode Design Non-polarized disposable hydrogel pads (interchangeable placement)
CPR Feedback Technology Integrated ICPR device measuring compression depth and rate
AHA Guideline Compliance Rates of 100–120 cpm; compression depth of 2.0–2.4 inches (5–6 cm)
Compatible Defibrillators Cardiac Science Powerheart G5 (Semi-Automatic & Fully Automatic)
Patient Intended Use Adults and children 8+ years of age or weighing 55+ lbs (25+ kg)
Standby Shelf Life 2 Years from date of manufacture
Storage Temperature 68°F to 86°F (20°C to 30°C); Short-term: 32°F to 122°F (0°C to 50°C)
Regulatory Status FDA PMA Approved (P160033) • CE Marked

Frequently Asked Questions

What is the difference between XELAED001B and XELAED002B?

Part XELAED001B contains standard adult defibrillation pads. Part XELAED002B includes the exact same medical defibrillation pads plus an integrated Intellisense CPR (ICPR) feedback sensor that provides real-time voice and text coaching on compression rate and depth.

Are XELAED002A and XELAED002B interchangeable?

Yes. XELAED002B is the current production model that superseded part XELAED002A. Both part numbers refer to genuine Cardiac Science Powerheart G5 adult CPR feedback electrodes and share identical fit, connectivity, and performance specs.

Are Powerheart G5 pads polarized?

No. Powerheart G5 pads are non-polarized, meaning either pad can be placed on the upper-right chest or the lower-left ribs. This eliminates placement hesitation during a rescue.

Can I use these pads on a child?

No. XELAED002B pads are calibrated for patients 8 years of age and older or over 55 lbs (25 kg). For infants and children under 55 lbs, order Powerheart G5 Pediatric Pads (XELAED003A).

Weight .55 lbs
Dimensions 8.5 × 6.0 × 1.0 in
Brand

Cardiac Science / ZOLL Medical

MPN

XELAED002B

Alternate Part Numbers

XELAED002A, XELAED002C

Product Type

Adult Defibrillation Electrodes with Intellisense CPR Feedback (ICPR)

Leadwire / Cable Length

51.5 inches (130 cm)

Electrode Placement

Non-Polarized (either pad can be placed on upper-right chest or lower-left ribs)

CPR Feedback Sensor

Pre-attached ICPR device (measures compression rate & depth in real time)

Standby Shelf Life

2 Years from manufacture date

Patient Application

Adults & Children 8+ years or 55+ lbs (25+ kg)

Defibrillator Compatibility

Cardiac Science Powerheart G5 (Semi-Automatic & Fully Automatic)

Operating / Storage Temp

68°F to 86°F (20°C to 30°C); Short-term: 32°F to 122°F (0°C to 50°C)

Pediatric Alternative

Intellisense Pediatric Defibrillation Pads (XELAED003A)

Regulatory Status

FDA PMA Approved (P160033), CE Marked

Packaging

Factory-sealed foil pouch with external pre-connected cable

Reviews

There are no reviews yet.

Be the first to review “Cardiac Science Powerheart G5 Adult Intellisense CPR Feedback Pads (XELAED002B / XELAED002A)”

Your email address will not be published. Required fields are marked *