Philips HeartStart FRx SMART Pads II (989803139261)
USE CODE: SAVE20
Official OEM replacement Philips HeartStart FRx SMART Pads II (Part # 989803139261). Apply coupon code SAVE20 at checkout for instant savings. These pre-connected electrodes serve both adults and children, eliminating the need to store separate pediatric pads.
- Universal 2-in-1 Design: Works for adults, children, and infants (when paired with the Infant/Child Key).
- Fresh Factory Expiration Dates: Guaranteed maximum remaining shelf life direct from Philips.
- Free FedEx Ground Shipping: Fast, tracked delivery straight from our Midwest facility.
Philips HeartStart FRx SMART Pads II (Part # 989803139261)
The Philips HeartStart FRx SMART Pads II (989803139261) are genuine OEM replacement electrode pads engineered specifically for the Philips HeartStart FRx Defibrillator (Model 861304). Packaged in a durable semi-rigid protective case, these SMART Pads II feature a pre-connected cable assembly that plugs directly into the AED while in storage, allowing the device to perform automated daily self-tests on pad readiness and gel moisture.
Unlike traditional AED pads that require purchasing and maintaining separate adult and child cartridges, the Philips FRx system uses a single universal electrode set. When treating an infant or child under 8 years of age or 55 pounds (25 kg), simply insert the reusable Philips HeartStart FRx Infant/Child Key into the AED. The device immediately reduces energy delivery from 150 Joules to 50 Joules and adapts CPR voice prompts for pediatric life support—saving valuable time and ongoing replacement costs.
Rescue Kit Readiness & Maintenance
Every set of Philips 989803139261 SMART Pads II carries a strict 2-year shelf life from the date of manufacture. Because the medical-grade hydrogel naturally dries over time, expired pads cannot reliably measure cardiac rhythm or deliver a therapeutic defibrillation shock. Check your AED components regularly to ensure rescue readiness:
Philips M5070A Long-Life Battery
If your pads have expired, your primary 4-year standby battery is likely nearing the end of its service life. The FRx AED uses the same non-rechargeable lithium manganese dioxide battery as the HeartStart OnSite.
Infant/Child Key (Part # 989803139311)
Turn your SMART Pads II into pediatric pads instantly. The reusable Infant/Child Key never expires and slots directly into the FRx faceplate to automatically lower defibrillation energy.
Key Features of Philips SMART Pads II
- Universal Adult & Pediatric Compatibility: One pad set handles adult rescues and converts immediately for infants and children when paired with the Infant/Child Key.
- Pre-Connected Design: Remains plugged into the AED during standby storage, ensuring the unit passes daily self-checks and is ready to deploy in seconds.
- Semi-Rigid Protective Case: Shielded against crushing, punctures, and moisture ingress in demanding industrial, fleet, and public safety environments.
- Intelligent SMART Sensing: Transmits real-time pad placement data back to the FRx unit to synchronize voice prompts with the rescuer’s progress.
- Extended 48-Inch Lead Wires: 1.2-meter cables give rescuers flexible positioning around the patient during CPR cycles.
- Advanced Life Support (ALS) Handoff: Compatible with Philips MRx, FR2, FR2+, and FR3 defibrillators, allowing quick patient transfer to incoming EMS teams using adapters.
Technical Specifications
| Specification | Detail |
|---|---|
| Manufacturer | Philips Healthcare |
| Manufacturer Part Number (MPN) | 989803139261 |
| UPC / GTIN-12 | 809046392618 |
| GTIN-14 | 00809046392618 |
| Compatible AED Models | Philips HeartStart FRx (861304) |
| Patient Weight Range | Adults & Children over 55 lbs (Standard); Infants & Children under 55 lbs (with Infant/Child Key) |
| Shelf Life | 2 Years from manufacture date |
| Conductor Surface Area | 80 cm² (12.4 sq in) per pad |
| Cable Length | 48 inches (121.9 cm) |
| Storage Temperature | 32° to 122°F (0° to 50°C) |
| Regulatory Compliance | FDA Cleared (PMA P180028), CE Marked |
Philips AED Compatibility Check
Always verify your AED model before ordering replacement pads. Defibrillator pads cannot be interchanged across different Philips unit lines:
- Philips HeartStart FRx (Model 861304): Compatible with these SMART Pads II (989803139261).
- Philips HeartStart OnSite (Model M5066A): Requires the snap-in M5071A Adult SMART Pads Cartridge or M5072A Infant/Child Cartridge.
- Philips HeartStart Home (Model M5068A): Requires the snap-in M5071A Adult SMART Pads Cartridge.
How to Install Your Replacement SMART Pads II
- Disconnect Old Pads: Pull the cable connector of the expired pad set straight out of the FRx pad connector port. Safely discard the expired pads.
- Inspect New Package: Remove the new SMART Pads II case from its box. Confirm that the packaging is intact and check the expiration date printed on the front label.
- Plug in Connector: Firmly insert the pad connector into the FRx port until it clicks securely into place.
- Confirm Readiness: Tuck the lead wire neatly into the storage groove and place the pad case into the FRx carry case. Look at the status indicator on the face of the AED—the green “Ready” light will flash to confirm proper connection.
Frequently Asked Questions
Do I need separate child pads for the Philips HeartStart FRx?
No. The Philips FRx uses these exact same SMART Pads II for adults, children, and infants. To treat a patient under 8 years old or under 55 lbs (25 kg), insert the Philips HeartStart FRx Infant/Child Key into the AED. The key automatically reduces shock energy and tailors voice coaching for pediatric care.
How long do Philips FRx SMART Pads II last?
SMART Pads II have a 2-year shelf life from the date of manufacture. The exact expiration date is printed clearly on the front of the pad package. Pads must be replaced upon reaching this date or immediately following use in a rescue.
Why are Philips FRx pads pre-connected?
Pre-connecting the pads allows the FRx defibrillator to run automated daily self-tests that evaluate electrode gel moisture and electrical integrity. It also saves vital seconds during a sudden cardiac arrest emergency by removing the step of plugging in cables.
Does AEDLand ship fresh pads?
Yes. We rotate stock continuously through our Midwest fulfillment center to guarantee you receive factory-fresh pads with maximum remaining shelf life directly from Philips Healthcare.
| Weight | 1 lbs |
|---|---|
| Dimensions | 10 × 6 × 1 in |
| Brand: | Philips Healthcare |
| MPN: | 989803139261 |
| Leadwire Length | 48 inches (121.9 cm) |
| Conductor Surface Area | 80 cm² (12.4 sq in) per pad |
| Packaging | Semi-rigid protective case |
| GTIN / UPC | 809046392618 |
| Compatibility | Philips HeartStart FRx (Model 861304 |
| Patient Application | Adult, Pediatric (Infant/Child with Key) |
| Patient Age/Weight | All ages; under 8 yrs / 55 lbs requires Infant/Child Key |

Leann Smith –
Perfect fit for my FRX AED and had a long expiration date.
Jane Nguyen –
I purchased the replacement Philips FRx SMART Pads II for our AED and wanted to make sure I was getting the official OEM pads. They arrived in good condition and were exactly what I needed. I appreciate knowing that these pads are specifically designed for the HeartStart FRx and can be used in both adult and pediatric situations when the Infant/Child Key is available.
Kerry Martin –
These Philips FRx SMART Pads II were a straightforward replacement for our HeartStart FRx. I specifically wanted genuine Philips pads instead of taking a chance on an unknown replacement. Everything arrived as expected, and it was reassuring to have the proper OEM electrodes on hand.
Audrey Belt –
Good experience ordering the Philips FRx SMART Pads II. We wanted to keep our AED supplies current and make sure we had official Philips replacement pads available. I also appreciate that the same pads support adult and pediatric rescues when used with the appropriate Infant/Child Key.